Published November 1998 | Version v1
Journal article

Evaluation of the safety and clinical feasibility of exercise 99mTc-MIBI SPECT using one day protocol. Multicenter phase III clinical trial report

Description

We evaluated the safety and clinical usefulness of the same day protocol of exercise 99mTc-MIBI SPECT in 107 patients with heart diseases. No adverse event was observed except for one case of transient hypotension caused by the exercise. More than 95% of stress images and all of the rest images were judged as 'Excellent' or 'Good' in image quality. Overall sensitivity was 84.3% in detecting coronary artery disease, and no statistical difference was observed between the results obtained with Re-Ex and Ex-Re protocols. The examination was 'Quite Effective' or 'Effective' in diagnostic efficacy in 96.2% of the cases. We concluded that the same day protocol is a safe and useful method for diagnosing myocardial ischemia, which provides high image quality and valuable information. (author)

Additional details

Publishing Information

Journal Title
Kaku Igaku
Journal Volume
35
Journal Issue
9
Journal Page Range
p. 929-938
ISSN
0022-7854