Penetration depth of nickel titanium and stainless steel finger spreaders incurred root canals

  • 1. Armed Forces Institute of Dentistry, Rawalpindi (Pakistan). Dept. of Operative Dentistry

Description

Objective: To compare, radiographically, the differences in the penetration depths of nickel titanium and stainless steel finger spreaders in curved root canals. Results: Penetration of nickel-titanium finger spreader was significantly (p<0.05) deeper than the stainless steel spreader of comparable size. The ease of stainless steel penetration deceased with increasing angle of curvature of the canal. Conclusion: Nickel-titanium spreaders may give better results for lateral condensation in curved canals because of their deeper penetration. (author)

Additional details

Publishing Information

Journal Title
JCPSP. Journal of the College of Physicians and Surgeons Pakistan
Journal Volume
13
Journal Issue
2
Journal Page Range
p. 70-72
ISSN