Calculation of quality factor for monoenergetic neutrons - in accordance with ICRU Report 40

  • 1. VNIIFTRI, Moscow (USSR)

Description

The quality factors for heavy particle dose in tissue from first interactions of monoenergetic neutrons calculated directly from the new quality factor determination given in ICRU Report 40 are presented as a function of neutron energy. The results of the calculation are compared with previously published calculations based on old concepts. For neutron energies from 100 keV up to 1 MeV these differences are about a factor of two. (author)