Evaluation of static eliminators containing polonium-210
Creators
- 1. Brookhaven National Lab., Upton, NY (United States). Environmental and Waste Technology Center
Description
Six static eliminators containing radioactive polonium-210 microspheres were examined subsequent to a contamination incident at a commercial facility. It was found that cracked and broken microspheres were being produced and incorporated into new devices and even as received devices were potential sources of contamination. It is shown that rough handling of the devices may initiate polonium-210 leakage during or prior to service. The epoxy binder used in the devices appears to suffer significant environmental and material damage even under ambient conditions. The effects of solvents, heat, moisture, or vibration during service may accelerate this damage. The breakdown of the epoxy binder appears to be a significant contributor to the contamination by loose microspheres or microsphere fragments
Additional details
Publishing Information
- Journal Title
- Materials Characterization
- Journal Volume
- 42
- Journal Issue
- 1
- Journal Page Range
- p. 13-20
- ISSN
- 1044-5803
- CODEN
- MACHEX
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 30038193
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S07: ISOTOPES AND RADIATION SOURCES;
- Descriptors DEI
- CONTAMINATION; ELECTROSTATIC CHARGE ELIMINATORS; EPOXIDES; FAILURES; LEAKS; MICROSPHERES; POLONIUM 210; SEALED SOURCES; SURFACE CONTAMINATION
- Descriptors DEC
- ALPHA DECAY RADIOISOTOPES; CONTAMINATION; DAYS LIVING RADIOISOTOPES; EVEN-EVEN NUCLEI; HEAVY NUCLEI; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; NANOSEC LIVING RADIOISOTOPES; NUCLEI; ORGANIC COMPOUNDS; ORGANIC OXYGEN COMPOUNDS; POLONIUM ISOTOPES; RADIATION SOURCES; RADIOISOTOPES