Assessment of SPECT images using UHRFB and other low-energy collimators in brain study by Hoffman phantom and manufactured defects
Creators
- 1. Gerash University of Medical Sciences. School of Paramedical (Iran, Islamic Republic of)
Description
The performance of collimators was investigated using low-energy high-resolution (LEHR) and low-energy ultra-high-resolution (LEUHR) collimators in SPECT system to study the brain physiology by injecting 99mTc-HMPAO radionuclide. Ultra-high-resolution fan beam (UHRFB) images were compared to other low-energy collimator images by constructed defects embedded into Hoffman brain phantom as lateral, deepness and metastasis designs with slices of Perspex. The defects were constructed by CNC machine as circular slices and ring flaws ranging in size from 2 to 16 mm to detect low-concentration regions. The data acquisition was done in tomographic mode with minimum radii and different matrix sizes, data acquisition time and number of projections. The collected data were reconstructed using two methods, filtered backprojection and ordered subset expectation maximization (OSEM). By two radiologists and via thallium and V-shaped markers, the minimum diameters of the constructed flaws inside the abnormal area of the brain phantom were diagnosed to 4.0 ± 0.4, 6.0 ± 0.7 and 8.0 ± 0.9 mm for UHRFB, LEUHR and LEHR, respectively. In OSEM method, the desirable ranges of the filter parameters were 4–8 iterations and 2–4 subsets for FB collimator. The outcomes showed that FB collimator provides the better resolution in axial, coronal and sagittal views using brain perfusion phantom and data from eight patients on tinnitus disease. The UHRFB with converging geometry confirmed the better detection of defect regions due to the lowest ratio of cold/background counts. This study may be useful for early detection of disease transference, monitoring of treatment response and disease progression.
Graphic abstract
A CNC machine was used to make disks for Hoffman brain phantom as metastases and ring defects in evaluation of SPECT images.Additional details
Identifiers
Publishing Information
- Journal Title
- European Physical Journal Plus
- Journal Volume
- 135
- Journal Issue
- 2
- Journal Page Range
- vp.
- ISSN
- 2190-5444
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 55062516
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BRAIN; COLLIMATORS; DATA ACQUISITION; DEFECTS; DETECTION; DIAGNOSIS; ENERGY RESOLUTION; FILTERS; IMAGES; METASTASES; PATIENTS; PERFORMANCE; PHANTOMS; PHYSIOLOGY; SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY; TECHNETIUM 99
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BODY; CENTRAL NERVOUS SYSTEM; COMPUTERIZED TOMOGRAPHY; DATA PROCESSING; DIAGNOSTIC TECHNIQUES; EMISSION COMPUTED TOMOGRAPHY; HOURS LIVING RADIOISOTOPES; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; MOCKUP; NERVOUS SYSTEM; NUCLEI; ODD-EVEN NUCLEI; ORGANS; PROCESSING; RADIOISOTOPES; RESOLUTION; STRUCTURAL MODELS; TECHNETIUM ISOTOPES; TOMOGRAPHY; YEARS LIVING RADIOISOTOPES
Optional Information
- Copyright
- Copyright (c) 2020 © Societ#Latin Small Letter A With Grave# Italiana di Fisica (SIF) and Springer-Verlag GmbH Germany, part of Springer Nature 2020