Published May 1988
| Version v1
Journal article
Support to operating power stations - some examples
Description
The paper describes the scope of the post-commissioning support work on operating AGR stations carried out by the National Nuclear Corporation (NNC). This includes the improvement work on Hinkley Point B, Hunterston B, Dungeness B and Hartlepool/Heysham 1 power stations. For Hinkley Point B, the support work has mainly been of the fuel discharge route, and for Hunterston B the work concerned the entry of about 8,000 litres of seawater into one of the reactor pressure vessels. Support work on Dungeness B included deficiencies in insulation of Upper pressure-vessel sidewall penetrations, and utilizing part of an active waste vault as an additional buffer store. (U.K.)
Additional details
Publishing Information
- Journal Title
- Marc
- Journal Volume
- 29
- Journal Issue
- 3
- Series
- Nucl. Eng.
- Journal Page Range
- 79-83
- ISSN
- 0368-2595
- CODEN
- NUEND
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 20006398
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- AGR TYPE REACTORS; DUNGENESS-B REACTOR; HARTLEPOOL REACTOR; HEYSHAM-A REACTOR; HINKLEY POINT-B REACTOR; HUNTERSTON-B REACTOR; REACTOR OPERATION; RESEARCH PROGRAMS; REVIEWS; UNITED KINGDOM ORGANIZATIONS
- Descriptors DEC
- CARBON DIOXIDE COOLED REACTORS; DOCUMENT TYPES; ENRICHED URANIUM REACTORS; GAS COOLED REACTORS; GRAPHITE MODERATED REACTORS; NATIONAL ORGANIZATIONS; OPERATION; POWER REACTORS; REACTORS; THERMAL REACTORS