Published February 2017 | Version v1
Journal article

Single-shot high-voltage circuit for electrical capacitance tomography

  • 1. Division of Nuclear and Medical Electronics, Institute of Radioelectronics and Multimedia Technology, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw (Poland)

Description

A new method of capacitance measurement for electrical capacitance tomography is presented. A single-shot excitation is used to accelerate measurement. A high-voltage pulse and oversampling of received signal are applied to obtain an acceptable signal-to-noise ratio. The results of measurements of standard capacitors and mutual capacitance of electrodes in 16 electrode tomographic sensors are presented. The elaborated circuit is stray-immune. It can measure capacitance in a range from about 1 fF to 1 pF at one gain setting with good linearity and precision at the rate of 20 000 samples per second. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/1361-6501/aa50e1

Additional details

Identifiers

Publishing Information

Journal Title
Measurement Science and Technology
Journal Volume
28
Journal Issue
2
Journal Page Range
[11 p.]
ISSN
0957-0233
CODEN
MSTCEP