X-ray diagnostics of target expansion due to fast plasma electron flux irradiation

  • 1. Budker Institute of Nuclear Physics, Novosibirsk (Russian Federation)

Description

A diagnostic technique for monitoring the plasma flow-induced thin target expansion is described. The technique involving an X-ray converter tube (XICT) was employed in GOL-3 facility experiments. 5 refs., 3 figs