Published June 2005 | Version v1
Journal article

Investigation on frictional pressure drop of steam-water two-phase flow in an internally ribbed tube

  • 1. Xi'an Jiaotong Univ., Xi'an (China). National Key Laboratory of Multiphase Flow in Power Engineering
  • 2. National Engineering Research Center-Power Equipment, Harbin (China)

Description

Within the range of pressures from 9 to 22 MPa, mass velocities from G 600 to 1200 kg/(m2·s), and heat fluxes from x 0 to 1.0, experiments had performed to investigate the frictional pressure drop of the steam-water two-phase flow in a six-head internally ribbed tube with the outer diameter of 38.1 mm and the thickness of 7.5 mm. The test section was thermally insulated as horizontal direction. Based on the experimental results, it was found that pressure had a noticeable effect on the frictional pressure drop of the mental results, and that pressure had a noticeable effect on the frictional pressure drop of the steam-water two-phase flow, and the frictional pressure drop factor of the steam-water two-phase flow decreased with an increase in pressure. The frictional pressure drop factor of the steam-water two-phase flow tends to one near the critical pressure. As steam quality increased, the frictional pressure drop factor of the steam-water two-phase flow first increased, and then it had a decreasing tendency. With an increase in mass velocity, the frictional pressure drop factor of the steam-water two-phase flow decreased. Correlations of the frictional pressure drop factor of the steam-water two-phase flow had been provided. (authors)

Additional details

Publishing Information

Journal Title
Nuclear Power Engineering
Journal Volume
26
Journal Issue
3
Journal Page Range
p. 228-232
ISSN
0258-0926

INIS

Optional Information

Notes
5 figs., 5 refs.