Published June 2017 | Version v1
Journal article

Calibrating non-central catadioptric vision system using local target reconstruction

  • 1. Key Laboratory of Precision Opto-mechatronics Technology, Ministry of Education, Beihang University, Beijing 100191 (China)
  • 2. Department of Electronic Information Engineering, Foshan University, Foshan 528000 (China)

Description

In a traditional catadioptric calibration process, a calibration target placed in different views is required and it leads to complexity in the calibration process. In order to simplify the calibration process of a non-central catadioptric vision system, we developed a local target reconstruction method used a circle-square-combined target. Each circle-square on the target is regarded as an independent sub-region. According to the local mapping of the sub-regions, these can be reconstructed based on the curvature of a curved mirror and the characteristics of the circle-square-combined target. The overall procedure requires a single image, due to the reconstructed sub-regions. To evaluate the performance of the proposed method, real experiments have been carried out and the results show that the proposed method is reliable and efficient. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/1361-6501/aa6784

Additional details

Identifiers

Publishing Information

Journal Title
Measurement Science and Technology
Journal Volume
28
Journal Issue
6
Journal Page Range
[10 p.]
ISSN
0957-0233
CODEN
MSTCEP

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
49035482
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
CALIBRATION; DIAGRAMS; IMAGES; MAPPING; MIRRORS; PERFORMANCE
Descriptors DEC
INFORMATION