Effects of moisture on the breakdown-pluse-noise of mineral-insulated instrument cable
Description
Cable resistances (R) and breakdown-pulse-noise (BPN) were measured before, during, and after heating 60-cm portions of a 10-meter mineral-insulated coaxial cable to various temperatures (T), mostly 3200C. A severe BPN-condition and a very low R within about 60 cm of the high-T end of the cable was shown to be due to atmospheric moisture admitted through an end-seal leak inflicted by a previous test. A similar, but much less severe, BPN-condition 90 to 120 cm removed from either end was attributed to a small amount of moisture that had collected at these positions during the same previous test independent of the end-seal leak. These results suggest that the BPN problem might be eliminated by better hygroscopic measures in cable manufacture. (U.S.)
Additional details
Identifiers
Publishing Information
- Journal Title
- IEEE Transactions on Nuclear Science
- Journal Volume
- 22
- Journal Issue
- 1
- Series
- IEEE (Inst. Electr. Electron. Eng.) Trans. Nucl. Sci.
- Journal Page Range
- 681-685
- ISSN
- 0018-9499
Conference
- Title
- 21. nuclear science symposium; 14. scintillation and semiconductor counter symposium; 6. nuclear power systems symposium.
- Dates
- 11 Dec 1974.
- Place
- Washington, DC.
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 6205342
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BREAKDOWN; COAXIAL CABLES; DIELECTRIC MATERIALS; HUMIDITY; MINERALS; NEUTRON DETECTORS; NOISE; REACTOR INSTRUMENTATION
- Descriptors DEC
- CONDUCTOR DEVICES; ELECTRIC CABLES; ELECTRICAL EQUIPMENT; MEASURING INSTRUMENTS; RADIATION DETECTORS
Optional Information