Published August 1985 | Version v1
Journal article

Application of a Schottky barrier diode mixer to a 118.8 μm laser interferometer

  • 1. Nagoya Univ. (Japan). Inst. of Plasma Physics

Description

Fundamental characteristics of a GaAs Schottky barrier diode mixer have been measured for the purpose of using it as the detector of a twin 118.8 μm CH3OH laser interferometer. The mixer sensitivity for beat oscillations of the twin lasers was measured in a frequency region from 1 MHz to 7 MHz. A signal to noise ratio of I.F. signal over 45 dB is obtained for the frequency up to 6 MHz. The dependence of the mixer sensitivity on local beam power was also measured. The I.F. signal level is approximately proportional to the local beam power in power level from 0.1 mW to 1.2 mW. (author)

Additional details

Publishing Information

Journal Title
Jpn. J. Appl. Phys., Part 2
Journal Volume
24
Journal Issue
8
Series
Jpn. J. Appl. Phys., Part 2.
Journal Page Range
L593-L595
CODEN