Published February 1978 | Version v1
Journal article

Build-up and depth-dose characteristics of different fast neutron beams relevant for radiotherapy

  • 1. Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands)

Description

Build-up and central axis depth-dose curves have been obtained for d(50)+Be, p(42)+Be and d+T neutron beams. Measurements carried out with the collimator opening covered with a layer of lead showed that for all three neutrons beams the entrance dose was approximately 60% of the dose at the maximum. Consequently the skin-sparing properties of these neutron beams are approximately equal and comparable to those for electron beam therapy. Central axis depth-dose curves have been established for d(50)+Be neutrons at 129 cm SSD, for p(42)+Be neutrons at 125 cm SSD and d+T neutrons and 60Co γ-rays at 80 cm SSD. The 50% dose values in a water phantom are at depths of 12.7 cm, 12.0 cm, 9.7 cm and 12.7 cm respectively, for field sizes of approximately 15 cm x 20 cm. Insertion of a 6 cm thick nylon filter in the p(42)+Be beam increased this value from 12.0 cm to 13.5 cm. The gamma component for the d+T neutron beam was higher than for the cyclotron beams. (author)

Additional details

Identifiers

Publishing Information

Journal Title
The British Journal of Radiology
Journal Volume
51
Journal Issue
602
Series
Br. J. Radiol.
Journal Page Range
122-126
ISSN
0005-1285

Optional Information

Notes
Updated automatically by Metadata and Full-Text Enrichment Agent