Published 1976 | Version v1
Report Restricted

Gamma, x-ray reduction system. Volume I: gamma

Creators

  • 1. Atlantic Richfield Hanford Co., WA

Description

The starting premises for this data reduction system were (a) the individual researcher needs all the accuracy that can be achieved but he has neither the time nor the inclination to learn how to achieve it, and (b) if the data reduction system is to be centralized the people operating it will want to minimize conversation with the computer. This is a working system. All spectral data are stored on Data General 4234 discs after background normalization and strip. Storage is initiated from magnetic tapes loaded by detached pulse height analyzers or directly from Scorpio pulse height analyzers. The only restrictions placed on the individual researchers are that the pulse height analyzer energy scale be set up consistently, that a recovery standard be run at least once every day of use, and the total acquisition system be calibrated to its range of use. In many instances, and if desirable, the latter is provided as a service. At the time of writing this gamma data reduction system is actively being used to calculate net peak areas, activities with or without time correction, activations analysis results, counting precisions, and dynamic limits of detection for the spectral data output of 17 detached pulse height analyzers. To all modes of data reduction are applied background subtraction, random summing correction, detector recovery factor correction, peak interfernce correction (second-order product interference for activation analysis), geometry function correction, acquisition time decay corrections, external and internal sorber correction. All of this is accomplished and a customer report typed in a readable format after a halfline of noninteractive instruction

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Title
Proceedings of ERDA symposium on x- and gamma-ray sources and applications
Imprint Pagination
p. 80-89.
Report number
CONF-760539--

Conference

Title
ERDA symposium on x- and gamma-ray sources and applications.
Dates
19 May 1976.
Place
Ann Arbor, Michigan, United States of America (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
8311201
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ACTIVATION ANALYSIS; DATA ACQUISITION SYSTEMS; DATA PROCESSING; GAMMA SPECTRA; GAMMA SPECTROMETERS; RADIOMETRIC ANALYSIS; SEMICONDUCTOR DETECTORS
Descriptors DEC
CHEMICAL ANALYSIS; MEASURING INSTRUMENTS; QUANTITATIVE CHEMICAL ANALYSIS; RADIATION DETECTORS; SPECTRA; SPECTROMETERS