Reproducibility of temporomandibular joint tomography. Influence of shifted X-ray beam and tomographic focal plane on reproducibility
Description
Proper tomographic focal plane and x-ray beam direction are the most important factors to obtain accurate images of the temporomandibular joint (TMJ). In this study, to clarify the magnitude of effect of these two factors on the image quality. We evaluated the reproducibility of tomograms by measuring the distortion when the x-ray beam was shifted from the correct center of the object. The effects of the deviation of the tomographic focal plane on image quality were evaluated by the MTF (Modulation Transfer Function). Two types of tomograms, one the plane type, the other the rotational type were used in this study. A TMJ model was made from Teflon for the purpose of evaluation by shifting the x-ray beam. The x-ray images were obtained by tilting the model from 0 to 10 degrees 2-degree increments. These x-ray images were processed for computer image analysis, and then the distance between condyle and the joint space was measured. To evaluate the influence of the shifted tomographic focal plane on image sharpness, the x-ray images from each setting were analyzed by MTF. To obtain the MTF, ''knife-edge'' made from Pb was used. The images were scanned with a microdensitometer at the central focal plane, and 0, 0.5, 1 mm away respectively. The density curves were analyzed by Fourier analysis and the MTF was calculated. The reproducibility of images became worse by shifting the x-ray beam. This tendency was similar for both tomograms. Object characteristics such as anterior and posterior portion of the joint space affected the deterioration of reproducibility of the tomography. The deviation of the tomographic focal plane also decreased the reproducibility of the x-ray images. The rotational type showed a better MTF, but it became seriously unfavorable with slight changes of the tomographic focal plane. Contrarily, the plane type showed a lower MTF, but the image was stable with shifting of the tomographic focal plane. (author)
Additional details
Publishing Information
- Journal Title
- Meikai Daigaku Shigaku Zasshi
- Journal Volume
- 27
- Journal Issue
- 3
- Journal Page Range
- p. 195-204
- ISSN
- 0916-0701
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 30035642
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; BONE JOINTS; COMPARATIVE EVALUATIONS; FOURIER TRANSFORMATION; IMAGES; JAW; PHANTOMS; RESINS; TEFLON
- Descriptors DEC
- BODY; DIAGNOSTIC TECHNIQUES; EVALUATION; INTEGRAL TRANSFORMATIONS; MATERIALS; MEDICINE; MOCKUP; ORGANIC COMPOUNDS; ORGANIC FLUORINE COMPOUNDS; ORGANIC HALOGEN COMPOUNDS; ORGANIC POLYMERS; ORGANS; PETROCHEMICALS; PETROLEUM PRODUCTS; PLASTICS; POLYETHYLENES; POLYMERS; POLYOLEFINS; SKELETON; SKULL; STRUCTURAL MODELS; SYNTHETIC MATERIALS; TRANSFORMATIONS