Published June 17, 2003 | Version v1
Report

Measurements of field decay and snapback effect on Tevatron dipole magnets

Description

The performance of Fermilab's Tevatron accelerator, currently in its Run II stage, is degraded by beam loss and emittance dilution during ramping from injection to collision energy. This could be related in part to insufficient compensation of dynamic effects such as the decay of the magnetic field in the dipoles during the dwell at injection and the following so-called snapback during the first few seconds of the energy ramp. The two effects are closely related and depend on the powering history of the magnets. Dynamic effects, which were originally discovered at the Tevatron, were investigated on Tevatron magnets in various past measurement campaigns in the 1980s and later in 1996. This paper reports on the most recent measurements performed on an additional set of Tevatron magnets

Availability note (English)

Available from https://www.osti.gov/servlets/purl/811865-biXIDx/native/

Additional details

Publishing Information

Imprint Pagination
478 Kilobytes
Report number
FERMILAB-Conf--03-108-E

Conference

Title
PAC 2003
Dates
12-16 May 2003
Place
Portland, OR (United States)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
34051731
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
DECAY; DILUTION; DIPOLES; FERMILAB TEVATRON; MAGNETIC FIELDS; MAGNETS; PERFORMANCE
Descriptors DEC
ACCELERATORS; CYCLIC ACCELERATORS; EQUIPMENT; MULTIPOLES; SYNCHROTRONS

Optional Information

Contract/Grant/Project number
AC--02-76CH03000
Funding organization