Published October 21, 2013 | Version v1
Journal article

Beam controlled arc therapy–a delivery concept for stationary targets

  • 1. Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD (United States)
  • 2. Department of Radiation Oncology, Emory University School of Medicine, Atlanta, GA (United States)

Description

Volumetric modulated arc therapy (VMAT) presupposes that it is beneficial to deliver radiation from all beam angles as the gantry rotates, requiring the multi-leaf collimator to maintain continuity in shape from one angle to another. In turn, radiation from undesirable beam angles could compromise the dose distribution. In this work, we challenge the notion that the radiation beam must be held on as the gantry rotates around the patient. We propose a new approach for delivering intensity-modulated arc therapy, beam-controlled arc therapy (BCAT), during which the radiation beam is controlled on or off and the dose rate is modulated while the gantry rotates around the patient. We employ linear-programming-based dose optimization to each aperture weight, resulting in some zero weight apertures. During delivery, the radiation beam is held off at control points with zero weights as the MLC shape transits to the next non-zero weight shape. This was tested on ten head and neck cases. Plan quality and delivery efficiency were compared with VMAT. Improvements of up to 17% (p-value 0.001) and 57% (p-value 0.018) in organ-at-risk sparing and target dose uniformity, respectively, were achieved. Compared to the fixed number of apertures used in single-arc and double-arc VMAT, the BCAT used 109 and 175 apertures on average, respectively. The difference in total MUs for VMAT and BCAT plans was less than 4%. Plan quality improvement was confirmed after delivery with γ analysis resulting in over 99% agreement, or 4 in 1099 points that failed. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/0031-9155/58/20/7117

Additional details

Identifiers

Publishing Information

Journal Title
Physics in Medicine and Biology
Journal Volume
58
Journal Issue
20
Journal Page Range
p. 7117-7129
ISSN
0031-9155
CODEN
PHMBA7

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
44113708
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
APERTURES; BEAMS; COLLIMATORS; DOSE RATES; HEAD; NECK; OPTIMIZATION; PATIENTS; RADIATION DOSE DISTRIBUTIONS; RADIATION DOSES; RADIOTHERAPY
Descriptors DEC
BODY; DOSES; MEDICINE; NUCLEAR MEDICINE; OPENINGS; RADIOLOGY; THERAPY