3T MRI of peripheral vascular malformations. Characteristics and comparison of two fat-saturated sequences. Short tau inversion recovery versus three-dimensional high-resolution volume interpolated gradient recalled echo
Creators
- 1. Clinic and Policlinic of Nuclear Medicine, University Hospital Würzburg (Germany)
- 2. Department of Radiology, University Hospital Regensburg (Germany)
- 3. Centre for Clinical Studies, University Hospital Regensburg (Germany)
- 4. University Clinic and Policlinic of Radiology, Martin Luther University Hospital Halle-Wittenberg, Halle (Saale) (Germany)
- 5. Department of Clinical Radiology, University Hospital Münster (Germany)
Description
To assess morphological and hemodynamic characteristics of peripheral vascular malformations on 3 T magnetic resonance imaging (MRI) including qualitative comparison of two fat-saturated sequences: short tau inversion recovery (STIR) and three-dimensional high-resolution volume interpolated gradient recalled echo (GRE). During 9 months, 100 patients with suspected or known vascular malformations were prospectively assessed on a 3 T scanner using T2-weighted STIR and turbo spin echo (TSE), T1-weighted TSE, time-resolved contrast-enhanced magnetic resonance angiography (MRA) with interleaved stochastic trajectories (TWIST) and T1-weighted volume interpolated breath-hold examination (VIBE) after contrast enhancement. The analysis included signal behavior and morphologic and hemodynamic characteristics. Additionally, the image quality of the fat-saturated sequences was evaluated by 2 radiologists. 86 patients (14 dropouts; 57 female, 29 male; mean age 26.8 years, age range 1–56) were analyzed. 22 had high-flow and 64 low-flow malformations, including 14 with a lymphatic component. In 21 of 22 patients with high-flow malformations, typical characteristics (flow voids, hyperdynamic arteriovenous fistula, dilated main/feeder-arteries and draining veins) were documented. Patients with low-flow malformations had phleboliths in 35 cases, fluid-fluid levels in 47 and dilated draining veins in 23. Lymphatic malformations showed peripheral contrast enhancement of cyst walls in the volume interpolated GRE. The comparison of fat-saturated sequences showed significantly better results of the volume interpolated GRE in all categories except the presence of artifacts which were significantly reduced in the STIR (p < 0.05). 3 T MRI with MRA provides detailed morphological and hemodynamic information of different types of peripheral vascular malformations. Contrast-enhanced high-resolution volume interpolated GRE proved superior to STIR in differentiating morphologic features and to be diagnostic in the differentiation of lymphatic parts and joint involvement.
Availability note (English)
Available from: http://dx.doi.org/10.1055/a-1253-8422Additional details
Identifiers
- DOI
- 10.1055/a-1253-8422;
Publishing Information
- Journal Title
- RoeFo - Fortschritte auf dem Gebiet der Roentgenstrahlen und der bildgebenden Verfahren
- Journal Volume
- 193
- Journal Issue
- 4
- Journal Page Range
- p. 446-458
- ISSN
- 1438-9029
- CODEN
- RFGNDO
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 52046639
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ARTERIES; BLOOD FLOW; CLASSIFICATION; COMPARATIVE EVALUATIONS; CONTRAST MEDIA; CYSTS; FISTULAE; IMAGE PROCESSING; LYMPHATIC SYSTEM; MAGNETIC FIELDS; MALFORMATIONS; NMR IMAGING; RELAXATION TIME; RESPIRATION; SPIN ECHO; STOCHASTIC PROCESSES; THREE-DIMENSIONAL CALCULATIONS; TIME RESOLUTION; VEINS; WEIGHTING FUNCTIONS
- Descriptors DEC
- BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; EVALUATION; FUNCTIONS; ORGANS; PATHOLOGICAL CHANGES; PROCESSING; RESOLUTION; TIMING PROPERTIES