Balloon pulmonary angioplasty: applicability of C-Arm CT for procedure guidance
Creators
- 1. Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover (Germany)
- 2. Department for Diagnostic and Interventional Radiology, Member of the German Center for Lung Research (DZL), Hannover Medical School, Hannover (Germany)
- 3. Clinic for Pneumology, Member of the German Center for Lung Research (DZL), Hannover Medical School, Hannover (Germany)
Description
To investigate the feasibility of and compare two C-Arm CT (CACT) guidance methods during balloon pulmonary angioplasty (BPA). Forty-two BPAs [27 CTEPH patients (nine males, 70 ± 14y)] targeting 143 pulmonary arteries were included. Twenty-two BPAs were guided by contrast-enhanced CACT acquired immediately before BPA (G3D). In another 20 BPAs (G2D), two orthogonal fluoroscopy images of the chest where acquired to compute a registration of a previously acquired CACT. Volume rendering-based graphic representations (VRT guidance) were generated indicating the origin and course of the vessels. Based on VRT guidance, the intervention was planned. Procedure durations and radiation exposure data were compared between the two groups (Wilcoxon test). The overall intervention time was approximately 2 h in both groups (p = 0.31). BPA was successfully performed in G3D 91 % and G2D 94 %. No significant difference was found concerning the mean dose area product (DAP) related to fluoroscopy (p = 0.38), while DAP related to DSA was slightly higher in G3D (p = 0.048). Overall, DAP was significantly higher in G3D (p = 0.002). The use of CACT for procedure guidance in patients undergoing BPA is feasible and accurate. Image fusion of a pre-acquired CACT can be used to decrease radiation exposure due to multiple BPA sessions. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-016-4280-zAdditional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 26
- Journal Issue
- 11
- Journal Page Range
- p. 4064-4071
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 48000280
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; BEAM PROFILES; BLOOD CIRCULATION; BLOOD FLOW; CARDIOVASCULAR SYSTEM; COMPUTERIZED TOMOGRAPHY; DIAGNOSIS; EMBOLI; FLUOROSCOPY; HYPERTENSION; LUNGS; RADIATION DOSES; RADIATION PROTECTION; THROMBOSIS
- Descriptors DEC
- BIOMEDICAL RADIOGRAPHY; BODY; CARDIOVASCULAR DISEASES; DIAGNOSTIC TECHNIQUES; DISEASES; DOSES; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; RESPIRATORY SYSTEM; SYMPTOMS; TOMOGRAPHY; VASCULAR DISEASES