Iodine X-ray fluorescence computed tomography system utilizing a cadmium telluride detector in conjunction with a cerium-target tube
Creators
- 1. 3rd Department of Surgery, Toho University School of Medicine, 2-17-6 Ohashi, Meguro-ku, Tokyo 153-8515 (Japan)
- 2. The 3rd Department of Surgery, Toho University School of Medicine, 2-17-6 Ohashi, Meguro-ku, Tokyo 153-8515 (Japan)
- 3. Department of Physics, Iwate Medical University, 2-1-1 Nishitokuta, Yahaba, Iwate 028-3694 (Japan)
- 4. Department of Microbiology, School of Medicine, Iwate Medical University, 19-1 Uchimaru, Morioka, Iwate 020-0023 (Japan)
- 5. Department of Neurosurgery, School of Medicine, Iwate Medical University, 19-1 Uchimaru, Morioka, Iwate 020-0023 (Japan)
- 6. Department of Electronics, Faculty of Engineering, Tohoku Gakuin University, 1-13-1 Chuo, Tagajo, Miyagi 985-8537 (Japan)
Description
An X-ray fluorescence computed tomography system (XRF-CT) is useful for determining the main atoms in objects. To detect iodine atoms without using a synchrotron, we developed an XRF-CT system utilizing a cadmium telluride (CdTe) detector and a cerium X-ray generator. CT is performed by repeated linear scans and rotations of an object. When cerium K-series characteristic X-rays are absorbed by iodine atoms in objects, iodine K fluorescence is produced from atoms and is detected by the CdTe detector. Next, event signals of X-ray photons are produced with the use of charge-sensitive and shaping amplifiers. Iodine Kα fluorescence is isolated using a multichannel analyzer, and the number of photons is counted using a counter card. In energy-dispersive XRF-CT, the tube voltage and tube current were 70 kV and 0.40 mA, respectively, and the X-ray intensity was 115.3 μGy/s at a distance of 1.0 m from the source. The demonstration of XRF-CT was carried out by the selection of photons in an energy range from 27.5 to 29.5 keV with a photon-energy resolution of 1.2 keV.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.nima.2011.02.108Additional details
Identifiers
- DOI
- 10.1016/j.nima.2011.02.108;
- PII
- S0168-9002(11)00590-0;
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 640
- Journal Issue
- 1
- Journal Page Range
- p. 170-175
- ISSN
- 0168-9002
- CODEN
- NIMAER
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 42097047
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- AMPLIFIERS; ATOMS; CADMIUM; CDTE SEMICONDUCTOR DETECTORS; CERIUM; COMPUTERIZED TOMOGRAPHY; DISPERSIONS; ENERGY RESOLUTION; FLUORESCENCE; IODINE; KEV RANGE 10-100; MULTI-CHANNEL ANALYZERS; PHOTONS; ROTATION; SYNCHROTRONS; X RADIATION; X-RAY FLUORESCENCE ANALYSIS
- Descriptors DEC
- ACCELERATORS; BOSONS; CHEMICAL ANALYSIS; CYCLIC ACCELERATORS; DIAGNOSTIC TECHNIQUES; ELECTROMAGNETIC RADIATION; ELECTRONIC EQUIPMENT; ELEMENTARY PARTICLES; ELEMENTS; EMISSION; ENERGY RANGE; EQUIPMENT; HALOGENS; IONIZING RADIATIONS; KEV RANGE; LUMINESCENCE; MASSLESS PARTICLES; MEASURING INSTRUMENTS; METALS; MOTION; NONDESTRUCTIVE ANALYSIS; NONMETALS; PHOTON EMISSION; PULSE ANALYZERS; RADIATION DETECTORS; RADIATIONS; RARE EARTHS; RESOLUTION; SEMICONDUCTOR DETECTORS; TOMOGRAPHY; X-RAY EMISSION ANALYSIS
Optional Information
- Copyright
- Copyright (c) 2011 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.