Published 1985
| Version v1
Journal article
Simulation of the ambient dose equivalent in a non-spherical phantom for photon energies from 10 keV to 1.25 MeV
Description
Monte Carlo calculations of dose equivalent in cuboid phantoms have been performed. The objective of these calculations is to select the dimensions of a phantom of suitable composition that will simulate ambient dose equivalent with acceptable uncertainties over a photon energy range from 10 keV to 1.25 MeV. The materials considered were ICRU soft tissue, MS20, Shonka plastic and PNL plastic. The results produced for the above materials and the problems encountered in trying to simulate ambient dose equivalent in a non-spherical phantom are presented. (author)
Additional details
Publishing Information
- Journal Title
- Radiat. Prot. Dosim.
- Journal Volume
- 11
- Journal Issue
- 3
- Series
- Radiat. Prot. Dosim.
- Journal Page Range
- 145-149
- ISSN
- 0144-8420
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 16071247
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- DOSE EQUIVALENTS; GAMMA DOSIMETRY; KEV RANGE 10-100; KEV RANGE 100-1000; MEV RANGE 01-10; MONTE CARLO METHOD; PHANTOMS
- Descriptors DEC
- DOSIMETRY; ENERGY RANGE; KEV RANGE; MEV RANGE; MOCKUP; STRUCTURAL MODELS