Published December 1999 | Version v1
Book

On the feasibility of using a spiral inflector in the central region of VEC

Creators

  • 1. Variable Energy Cyclotron Centre, Calcutta (India)

Description

The heavy ion beam from the ECR ion source is transported to the central region of VEC using an axial injection system. In this work an attempt has been made to find out a suitable geometry of a spiral inflector which in combination with the present central region will produce well centered beam without any modification of the existing accelerating electrodes

Part of:
DAE symposium on nuclear physics: contributed papers. V. 42B

Additional details

Publishing Information

Publisher
Bhabha Atomic Research Centre
Imprint Place
Mumbai (India)
Imprint Title
DAE symposium on nuclear physics: contributed papers. V. 42B
Imprint Pagination
505 p.
Journal Page Range
p. 430-431

Conference

Title
DAE symposium on nuclear physics
Dates
27-31 Dec 1999
Place
Chandigarh (India)

INIS

Country of Publication
India
Country of Input or Organization
India
INIS RN
32010180
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ASPECT RATIO; BEAM INJECTION; ECR ION SOURCES; ELECTRIC POTENTIAL; ELECTROSTATIC MIRRORS; MAGNETIC FIELDS; RUNGE-KUTTA METHOD; VARIABLE ENERGY CYCLOTRONS
Descriptors DEC
ACCELERATORS; CALCULATION METHODS; CYCLIC ACCELERATORS; CYCLOTRONS; INTERPOLATION; ION SOURCES; ITERATIVE METHODS; MIRRORS; NUMERICAL SOLUTION

Optional Information

Notes
1 ref., 1 fig.