Published 1996 | Version v1
Journal article

Preliminary assessment of LiF and alanine detectors for the dosimetry of proton therapy beams

  • 1. Istituto Nazionale di Fisica Nucleare, Rome (Italy). Sezione Sanita
  • 2. Istituto Superiore di Sanita, Rome (Italy)
  • 3. Istituto Nazionale di Fisica Nucleare, Pisa (Italy)
  • 4. Pisa Univ. (Italy). Dipt. di Costruzioni Meccaniche e Nucleari
  • 5. Paul Scherrer Inst. (PSI), Villigen (Switzerland)

Description

An experimental intercomparison between the proton response of LiF TLD-100 and alanine detectors is reported. The investigations were performed with LiF chips and alanine pellets in a 62 MeV proton beam at the Paul Scherrer Institut in Villigen (CH). Results were compared with reference dosimetry provided by Markus type parallel plate ionization chamber. The response of the detectors was studied, in a phantom, at different beam penetration depths in pristine and modulated beams. For both alanine and TL detectors, within the experimental uncertainty of the measurements, no significant energy dependence in the response was observed down to the Bragg peak region. The sensitivity of alanine and LiF detectors to protons was measured in the centre of modulated Bragg peak and no significant difference was found with respect to 60Co. Contrary to LiF, alanine also offers a remarkable tissue equivalence which favours its choice for in-phantom dosimetry. (author)

Additional details

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
66
Journal Issue
1-4
Journal Page Range
p. 305-309.
ISSN
0144-8420
CODEN
RPDODE

Conference

Title
11. international conference on solid state dosimetry.
Dates
10-14 Jul 1995.
Place
Budapest (Hungary).

Optional Information

Secondary number(s)
CONF--950708.