Published April 15, 1979 | Version v1
Journal article

A 700 keV tandem accelerator

  • 1. Tsukuba Univ., Sakura, Ibaraki (Japan). Tandem Accelerator Center

Description

A very small tandem accelerator with 300 kV terminal voltage was constructed to obtain various technical data for the advanced design of a Lamb-shift type polarized ion source for the 12 UD Pelletron tandem accelerator. The beam transmission for hydrogenic ions was as high as 40% at terminal voltages around 300 kV with carbon foil strippers of 10 μg/cm2 thickness. (Auth.)

Additional details

Publishing Information

Journal Title
Nucl. Instrum. Methods
Journal Volume
161
Journal Issue
1
Series
Nucl. Instrum. Methods.
Journal Page Range
9-12
ISSN
0029-554X

INIS

Country of Publication
Netherlands
Country of Input or Organization
Netherlands
INIS RN
10484865
Subject category
S43: PARTICLE ACCELERATORS;
Descriptors DEI
CONSTRUCTION; HYDROGEN IONS; ION SOURCES; KEV RANGE 100-1000; LAMB SHIFT; OPERATION; VAN DE GRAAFF ACCELERATORS
Descriptors DEC
ACCELERATORS; CHARGED PARTICLES; ELECTROSTATIC ACCELERATORS; ENERGY RANGE; IONS; KEV RANGE; SPECTRAL SHIFT