Improvement of the calibration technique of clinical dosemeters
- 1. Instituto de Pesquisas Energeticas e Nucleares, Sao Paulo (Brazil)
Description
Clinical dosemeters constituted of ionization chambers connected to electrometers are usually calibrated as whole systems in appropriate radiation fields against secondary standard dosemeters in calibration laboratories. This work reports on a technique of component calibration procedures separately for chambers and electrometers applied in the calibration laboratory of IPEN-CNEN, Brazil. For electrometer calibration, redundancy was established by using a standard capacitor of 1000pF (General Radio, USA) and a standard current source based on air ionization with Sr90 (PTW, Germany). The results from both methods applied to several electrometers of clinical dosemeters agreed within 0.4%. The calibration factors for the respective chambers were determined by intercomparing their response to the response of a certified calibrated chamber in a Co60 calibration beam using a Keithley electrometer type 617. Overall calibration factors compared with the product of the respective component calibration factors for the tested dosemeters showed an agreement better than 0.7%. This deviation has to be considered with regard to an uncertainty of 2.5% in routine calibration of clinical dosemeters. Calibration by components permits to calibrate ionization chambers one at a time for those hospitals who have several ionization chambers but only one electrometer (small hospitals, hospitals in developing countries). 6 refs, 2 figs, 2 tabs
Files
19095990.pdf
Files
(168.3 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:d1c1d5d45479501e08a71f29500cef5f
|
168.3 kB | Preview Download |
Additional details
Additional titles
- Subtitle (English)
- Final report for the period September 1985 - December 1987
Publishing Information
- Imprint Pagination
- 12 p.
- Report number
- IAEA-R--4163-F
INIS
- Country of Publication
- International Atomic Energy Agency (IAEA)
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 19095990
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- CALIBRATION; CALIBRATION STANDARDS; DOSEMETERS; ELECTROMETERS; IONIZATION CHAMBERS; RADIATION MONITORS; RADIOTHERAPY; SSDL
- Descriptors DEC
- ELECTRIC MEASURING INSTRUMENTS; ELECTRICAL EQUIPMENT; EQUIPMENT; MEASURING INSTRUMENTS; MEDICINE; MONITORS; RADIATION DETECTORS; THERAPY