Published February 15, 1986
| Version v1
Journal article
The 'portico' in the Munich MP-tandem
- 1. Beschleunigerlaboratorium der Univ. und Technischen Univ. Muenchen, Garching (Germany, F.R.)
- 2. Muenchen Univ. (Germany, F.R.). Sektion Physik
Description
A ''portico'' was installed with the aim of preventing spark damage to column components and of increasing the terminal voltage. First experiences: no spark damage is observed, especially deconditioning of accelerating tubes by the sparks has disappeared. No significant increase in terminal voltage due to axial effects has been attained. (orig.)