Published June 1984 | Version v1
Report Restricted

Two-phase 3 x 3 rod bundle test facility for post-critical heat flux boiling

Description

This report describes the rod bundle post-CHF tests in progress and the test facility at Lehigh University. The mechanical and electrical design of the experimental facility and the iterative process used to arrive at the choices made for the design are described in detail. The test facility consists of a nine (3 x 3) rod bundle in a square shroud which form the test section together with the hot patches at the top and bottom ends. The rods and the hot patches are electrically heated while the shroud is radiatively heated. The test section includes instrumentation to measure the vapor superheat temperature and pressure drop upstream and downstream of a rod gap spacer. This is the first application of the hot patch technique for generating post-CHF conditions in a rod bundle and thus quasi-steady-state tests are being thought of as a backup procedure for conducting these post-CHF heat transfer tests. The test section is part of a well instrumented recirculating loop to generate the desired post-CHF conditions. The other major components of the heat transfer loop include the surge tank, pumps, boiler, separation tank and condenser

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A04/MF A01 - GPO* $4.25 as TI84901536.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Augmented title (English)
PWR; BWR

Publishing Information

Imprint Pagination
56 p.
Report number
NUREG/CR--3849