Measurements of the spatial distribution of tritium in air above a chronically contaminated surface

Description

Tritium in air (HTO) concentrations were measured over a 13 month period above a surface that is chronically contaminated by tritium-bearing groundwater from a waste management area. The measurements were made using passive diffusion samplers, which were sited at six locations (about 100 m apart) at 0.15, 0.9, and 1.8 m above ground level. The diffusion samplers were compact, sampled at a known rate, and required no external power source. They are ideal for remote locations and require a minimum of effort to collect and analyze the data. HTO-in-air concentration peaked in the summer at 500-1500 Bq.m-3 and decreased in the winter to 1-120 Bq.m-3. In general, concentration decreased with height above ground level, implying that HTO is being lost from the surface to the atmosphere. The flux of tritium to the atmosphere must, therefore, be taken into account to estimate the tritium mass balance for a contaminated area. (Author) 3 figs., 5 tabs., 10 refs

Availability note (English)

MF available from INIS under the Report Number.

Files

25025377.pdf

Files (292.7 kB)

Name Size Download all
md5:666e991b5fa4417cc5f24fbe503e034a
292.7 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
18 p.
Report number
AECL--10752