Published November 2013 | Version v1
Journal article

Measuring the capability of resisting 14 MeV neutron yawp of domestic LaCl3 scintillator

  • 1. Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang (China)

Description

When measuring γpulse in 14 MeV neutron radiation field with LaCl3 scintillator, the γ sensitivity is necessarily know. At the same time, the capability of resisting 14 MeV neutron yawp should also be necessarily know, too. In this paper, the γ sensitivities of LaCl3 and CeF3 are measured in steady γ radiation field, and the neutron sensitivities of both are measured in 14 MeV pulse neutron radiation field which FWHM is about 10-6 s. The capability of resisting 14 MeV neutron yawp of LaCl3 scintillator is calculated according to that of CeF3 scintillator. The result shows that the capability of resisting 14 MeV neutron yawp of LaCl3 is comparative with that of CeF3. The ratio of above results adopting electric charge method is 1, the ratio of above results adopting peak value method is closely 2. The ratio of capability of resisting 14 MeV neutron yawp of LaCl3 and ST401 is more 10. (authors)

Additional details

Publishing Information

Journal Title
Nuclear Electronics and Detection Technology
Journal Volume
33
Journal Issue
4
Journal Page Range
p. 1342-1345
ISSN
0258-0934

Optional Information

Notes
1 figs., 2 tabs., 19 refs.