The effect of serial data collection on the accuracy of electrical impedance tomography images
Creators
- 1. Sir Harry Smith Community College, Whittlesey, PE7 1XB (United Kingdom)
- 2. Department of Natural Science, Middlesex University, London, NW 4BT (United Kingdom)
Description
There has been a surge of interest in using electrical impedance tomography (EIT) for monitoring regional lung ventilation, however, EIT is an ill-conditioned problem, and errors/noise in the boundary voltages can have an undesirable effect on the quality of the final image. Most EIT systems in clinical usage use serial data collection hence data used to create a single image will have been collected at different times. This paper presents a study of the resulting image distortion, and proposes a method for correcting this lag in situations where the frame rate is insufficient to prevent significant image degradation. Significant correlation between the standard deviation of the time dependent reciprocity error and time delay dLe between the reciprocal electrode combinations was found for both adult and neonate data. This was reduced when the data was corrected for dLe. Original and corrected data was reconstructed with the GREIT algorithm and visible differences were found for the neonate data. Ideally EIT systems should be run at a frame rate of at least 50 times the frequency of the dominant and interesting physiological signals. Where this is not practical, the intra-frame system timings should be determined and lag corrected for. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/0967-3334/34/6/659Additional details
Identifiers
Publishing Information
- Journal Title
- Physiological Measurement (Print)
- Journal Volume
- 34
- Journal Issue
- 6
- Journal Page Range
- p. 659-669
- ISSN
- 0967-3334
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 47049860
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S75: CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY;
- Descriptors DEI
- ACCURACY; ADULTS; ALGORITHMS; DATA COMPILATION; ELECTRIC IMPEDANCE; ELECTRIC POTENTIAL; ELECTRODES; ERRORS; IMAGE PROCESSING; IMAGES; INFANTS; LUNGS; MONITORING; NEONATES; NOISE; SIGNALS; TIME DELAY; TIME DEPENDENCE; TOMOGRAPHY; VENTILATION
- Descriptors DEC
- AGE GROUPS; ANIMALS; BODY; CHILDREN; DATA; DATA PROCESSING; DIAGNOSTIC TECHNIQUES; IMPEDANCE; INFORMATION; MAMMALS; MAN; MATHEMATICAL LOGIC; ORGANS; PRIMATES; PROCESSING; RESPIRATORY SYSTEM; VERTEBRATES