OTSG tube failures: upper tubesheet corrosion tests. Final report

Description

Several Alloy 600 tubes adjacent to the open lanes in the Oconee IB and IIB once-through steam generator failed near their juncture with the upper tubesheet. To help define the probable mechanism for these failures, a laboratory test program was undertaken. The test program indicated that the corrosion damage in the Oconee steam generators was probably caused by alkaline concentrates of sodium sulfate, silicate, and chloride. Actions taken to avoid this type of damage include reduction of contaminant levels in the steam generators feedwater and use of lane blockers to avoid transport of water droplets up the open lanes

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A05/MF A01 as DE83901118.