Analysis of main influence factors on coronary artery image quality with 64-multidetector row helical CT using a pulsating cardiac phantom
- 1. Department of Radiology, the First Affiliated Hospital of Anhui Medical Univ., Hefei (China)
Description
Objective: To explore the main influence factors (heart rate, rotation speed, and reconstruction algorithm) on the image quality of coronary artery with 40 mm VCT (64-detector row helical CT) using a pulsating cardiac phantom. Methods: An adjustable pulsating cardiac phantom (GE) containing predetermined simulated coronary arteries was scanned using a 40 mm VCT (GE LightSpeed CT) with cardiac pulsating rates of 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, and 115 beats per minute (bpm). The variable rotation speeds technique of 0.35 s, 0.40 s, and 0.45 s were used, respectively. The raw data were reconstructed using both one-sector and multi-sector reconstruction algorithm at optimal window of the R-R interval. The image quality score (IQS) was evaluated by two radiologists according to the same evaluation standard of reformated image. The correlation between heart rate (HR), roation speed, reconstruction algorithm, and IQS were analyzed. The IQS as independent variable and the HR, rotation speed, reconstruction algorithm as dependent variables were analyzed by multiple linear regression analysis. Results: The heart rate and the reconstruction algorithm had significant influence on IQS. The rotation speed (0.35s, 0.40 s, and 0.45 s) didn't have significant influence on IQS. There was linear regression relationship between heart rate, reconstruction algorithm and IQS (P<0.01). The equation of multiple regression was IQS=5.154-0.046 x (HR) + 0.500 x (reconstruction algorithm). The multi-sector reconstruction algorithm improved the image quality than one-sector did. Conclusion: The main influence factors on the image quality of coronary artery can be evaluated with 40 mm VCT using a pulsating cardiac phantom. It plays an important role in clinical research and application. (authors)
Additional details
Publishing Information
- Journal Title
- Chinese Journal of Radiology
- Journal Volume
- 40
- Journal Issue
- 9
- Journal Page Range
- p. 980-983
- ISSN
- 1005-1201
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 39111245
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ALGORITHMS; CAT SCANNING; CORONARIES; CORRELATIONS; DIAGNOSTIC TECHNIQUES; EQUATIONS; EVALUATION; HEART; IMAGES; PHANTOMS; QUALITY ASSURANCE; REGRESSION ANALYSIS; SIMULATION; WINDOWS
- Descriptors DEC
- ARTERIES; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; MATHEMATICAL LOGIC; MATHEMATICS; MOCKUP; OPENINGS; ORGANS; STATISTICS; STRUCTURAL MODELS; TOMOGRAPHY
Optional Information
- Notes
- 4 figs., 2 tabs., 10 refs.