Civil and hydraulic engineering facilities of the coolant supply system and the harbour for large equipment
Creators
- 1. Melyepitesi Tervezoe Vallalat, Budapest (Hungary)
Description
The harbour which is in the cold channel, was designed so as to facilitate the landing of the ship transporting the reactor vessel. The coolant stream of the ternary circuit of the plant is about 380 000 m3 fresh water per hour. The cold channel, the pumping station, the filtering reservoir, the tubing, the hot channel were planned to meet this coolant demand. (V.N.) 7 figs
Additional details
Additional titles
- Original title (Hungarian)
- A huetoevizellatas mely- es vizepitesi letesitmenyei, a nagyberendezesek kikoetoeje
- Augmented title (English)
- at the Paks nuclear power plant
Publishing Information
- Journal Title
- Magyar Epitoeipar
- Journal Volume
- 37
- Journal Issue
- 5-6
- Series
- Magy. Epitoeipar.
- Journal Page Range
- 260-264
- ISSN
- 0025-0074
- CODEN
- MGYEA
INIS
- Country of Publication
- Hungary
- Country of Input or Organization
- Hungary
- INIS RN
- 20019294
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- COOLANTS; DANUBE RIVER; HARBORS; HOT CHANNEL; OPEN-CYCLE COOLING SYSTEMS; PAKS-1 REACTOR; PUMPS; REACTOR COOLING SYSTEMS; WATER
- Descriptors DEC
- COOLING SYSTEMS; ENRICHED URANIUM REACTORS; EQUIPMENT; HYDROGEN COMPOUNDS; OXYGEN COMPOUNDS; POLAR SOLVENTS; POWER REACTORS; PWR TYPE REACTORS; REACTOR COMPONENTS; REACTORS; RIVERS; SOLVENTS; SURFACE WATERS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS; WWER TYPE REACTORS
Optional Information
- Notes
- From a collection of articles on the construction of the Paks NPP.