The influence of equipment properties on dose distribution in a cobalt 60 gamma irradiation facility
Description
The thesis deals with the improvement of a computer programme for calculating dose distributions in Co-60 teletherapy involving matching of dose distributions in the irradiation field to the new gamma irradiation facility Siemens Gammatron S80. Dose distribution (isodose plan) comprises the depth does curve parallel to central beam and the different dose cross distribution curves perpendicular to central beam at each phantom depth to be studied. Measurements and curves provided the base for an improvement of the available form of the 'COMRAD' computer programme. The curves were parametered and incorporated in the 'COMRAD' programme using an especially developed calculation method. For an assessment of the efficiency of the new programme, vertical field isodoses were calculated under different conditions using both the old and new programme, and were directly compared graphically. (orig./HP)
Availability note (English)
Available from the library of Heidelberg Univ. (Germany, F.R.).Abstract (German)
Die Arbeit befasst sich mit der Verbesserung eines Rechnerprogrammes zur Berechnung von Dosisverteilungen in der Co-60-Teletherapie mit einer Anpassung der Dosisverteilungen in den Bestrahlungsfeldern an eine neue Gammabestrahlungsanlage SIEMENS GAMMATRON S 80. Die Dosisverteilung (Isodosenplan) setzt sich zusammen aus der Tiefendosiskurve entlang des Zentralstrahls und den verschiedenen Dosis-Querverteilungskurven senkrecht zum Zentralstrahl in der jeweils interessierenden Phantomtiefe. Die Messungen und Kurven bildeten die Grundlage fuer eine Verbesserung des Rechenprogrammes 'COMRAD' in seiner vorhandenen Form. Nach Parametrisierung der Kurven wurden diese durch ein speziell entwickeltes Berechnungsverfahren in das Programm 'COMRAD' eingebaut. Zur Beurteilung der Leistungsfaehigkeit des neuen Programms wurden unter verschiedensten Bedingungen Stehfeldisodosen, jeweils nach dem alten und dem neuen Programm berechnet, und direkt graphisch miteinander verglichen. (orig./HP)Additional details
Additional titles
- Original title (German)
- Einfluss von Geraeteeigenschaften auf die Dosisverteilung an einer Kobalt 60 - Gammabestrahlungsanlage
Publishing Information
- Imprint Pagination
- 91 p.
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 17055092
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE; S07: ISOTOPES AND RADIATION SOURCES;
- Resource subtype / Literary indicator
- Thesis, Non-conventional Literature
- Descriptors DEI
- COBALT 60; COMPUTER CALCULATIONS; DEPTH DOSE DISTRIBUTIONS; GAMMA SOURCES; IRRADIATION PROCEDURES; ISODOSE CURVES; PATIENTS; PHANTOMS; PLANNING; RADIOTHERAPY
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; COBALT ISOTOPES; DISTRIBUTION; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTO; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; MEDICINE; MINUTES LIVING RADIOISOTOPES; MOCKUP; NUCLEI; ODD-ODD NUCLEI; RADIATION DOSE DISTRIBUTIONS; RADIATION SOURCES; RADIOISOTOPES; SPATIAL DISTRIBUTION; SPATIAL DOSE DISTRIBUTIONS; STRUCTURAL MODELS; THERAPY; YEARS LIVING RADIOISOTOPES