Published February 1, 2004 | Version v1
Journal article

Digital pulse shape discrimination in organic scintillators for fusion applications

Description

Stilbene and NE213 organic scintillators are commonly used for neutron and γ-ray detection in mixed n/γ fields due to their pulse shape discrimination properties. A system for n/γ digital pulse shape discrimination (DPSD) and simultaneous pulse height analysis using a commercial 12-bit 200 MHz transient recorder is presented. The results of measurements performed on the fusion experiment FTU (Frascati Tokamak Upgrade) are described. The importance of DPSD for fusion applications and its advantages with respect to analog PSD are analyzed