Published May 1, 1987 | Version v1
Journal article

Highly precise field measurement of the TOPAZ magnet at the TRISTAN collider

  • 1. National Lab. for High Energy Physics, Oho, Ibaraki (Japan)

Description

The magnetic field distribution of the TOPAZ detector for the 30x30 GeV e+e- colliding beam experiment at TRISTAN, has been measured very precisely over a volume of 2.3 m in diameter and 4.2 m in length. This paper will describe the details of the reconstruction procedure of the field distribution from the measured data and the results of a comparison with a POISSON estimation. An accuracy of 10-4 in the measurement of Bperpendicularto/Bz hs been achieved. (orig.)

Additional details

Publishing Information

Journal Title
Nucl. Instrum. Methods Phys. Res., Sect. A
Journal Volume
256
Journal Issue
2
Series
Nucl. Instrum. Methods Phys. Res., Sect. A.
Journal Page Range
272-284
ISSN
0168-9002
CODEN
NIMAE