Research on thermodynamic performance of a novel building cooling system integrating dew point evaporative cooling, air-carrying energy radiant air conditioning and vacuum membrane-based dehumidification (DAV-cooling system)

  • 1. National Center for International Research Collaboration in Building Safety and Environment, Hunan University, Changsha 410082 (China)
  • 2. Key Laboratory of Building Safety and Energy Efficiency Ministry of Education, Hunan University, Changsha 410082 (China)
  • 3. College of Civil Engineering, Hunan University, Changsha 410082 (China)
  • 4. Department of Mechanical Engineering, National University of Singapore, Singapore 117575 (Singapore)

Description

Highlights: • A novel building cooling system (DAV-cooling system) is proposed. • A validated thermodynamic model of DAV-cooling system is established. • The parameters of the DAV cooling system are systematically analyzed. • The engineering design methods of DAV-cooling system are discussed. In this work, a novel building cooling system is proposed, namely DAV-cooling system, which integrates dew point evaporative cooling, air-carrying energy radiant air conditioning and vacuum membrane-based dehumidification. The DAV-cooling system does not use any organic refrigerants, and can naturally provide fresh air indoors to prevent managers from arbitrarily reducing fresh air, and can be flexibly adjusted to meet different cooling requirements. In addition, the thermodynamic model of the DAV-cooling system is established, and some systematical analysis of parameters of the DAV-cooling system is carried out. The results indicate that there is an optimal ratio of fresh air to primary air for the DAV-cooling system, and the optimal value of this ratio should be in the range of 0.2–0.4. When the DAV-cooling system operates under the condition of a higher flow of primary air, the requirements for the dehumidification efficiency of the vacuum membrane-based dehumidification device can be reduced. Moreover, the relationship between COP and cooling capacity ratio is revealed, and it is found that COP decreases as the cooling capacity ratio increases, but they are not in an absolutely one-to-one relationship. Outdoor temperature and humidity also have a greater impact on the performance of the DAV-cooling system. For Singapore and Changsha in the period from June to August, the COP of the DAV-cooling system is about 5–7 and 4.5–9 respectively when the permeate side pressure is 20 kPa. Finally, the engineering design methods of the DAV-cooling system are discussed, and it is found that the DAV-cooling system can be designed as a temperature and humidity independent control air conditioning system through the proposed design method and the established model. This work can provide a complete solution reference and some new insights for the application of next-generation HVAC systems.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.enconman.2021.114551

Additional details

Identifiers

DOI
10.1016/j.enconman.2021.114551;
PII
S0196890421007275;

Publishing Information

Journal Title
Energy Conversion and Management
Journal Volume
245
Journal Page Range
vp.
ISSN
0196-8904
CODEN
ECMADL

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
54031105
Subject category
S42: ENGINEERING; S71: CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS;
Descriptors DEI
AIR CONDITIONING; COOLING SYSTEMS; DEHYDRATION; DRYING; EVAPORATIVE COOLING; MEMBRANES; PERFORMANCE; THERMODYNAMIC MODEL; THERMODYNAMICS
Descriptors DEC
COOLING; ENERGY SYSTEMS; MATHEMATICAL MODELS; PARTICLE MODELS; STATISTICAL MODELS

Optional Information

Copyright
Copyright (c) 2021 Elsevier Ltd. All rights reserved.