The objective of this study is to develop nuclear heating measurement methods in Zero Power experimental reactors. This paper presents the analysis of Thermo-Luminescent Detector (TLD) and Optically Stimulated Luminescent Detectors (OSLD) experiments in the UO2 core of the MINERVE research reactor at the CEA Cadarache. The experimental sources of uncertainties on the gamma dose have been reduced by using the optimum conditions of charged particle equilibrium (CPE) of the calibration step for each individual TLD. The interpretation of these measurements needs to take into account calculation of cavity correction factors, related to calibration and irradiation configurations, as well as neutron corrections calculations. These calculations are based on Monte Carlo simulations of neutron-gamma and gamma-electron transport coupled particles. TLD and OSLD are positioned inside aluminum pillboxes. The comparison between calculated and measured integral gamma-ray absorbed doses using TLD, shows that calculation slightly overestimates the measurement with a calculation versus experiment (C/E) ratio value equal to 1.05 ± 5.3% (k = 2). By using OSLD, the calculation slightly underestimates the measurement with a C/E value equal to 0.96 ± 7.0% (k = 2). (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1109/TNS.2012.2197637

Additional details

Identifiers

Publishing Information

Journal Title
IEEE Transactions on Nuclear Science
Journal Volume
59
Journal Issue
no.4
Journal Page Range
p. 1360-1368
ISSN
0018-9499

Optional Information

Notes
22 refs.