Published November 1993
| Version v1
Journal article
The determination of lead and cadmium in dusts by DPASV
Creators
- 1. The Open Univ., Milton Keynes (United Kingdom). Faculty of Technology
Description
The simultaneous determination of Pb and Cd in dust by differential pulse anodic stripping voltammetry (DPASV) at the hanging mercury drop electrode is described with reference to the effects of pH, supporting electrolytes and interfering ions. In solutions of pH 2-5 at the established optimum conditions, the determinations were reproducible with a relative standard deviation of 10%. The detection limit is 0.1 ppb for both lead and cadmium. The accuracy and precision of the method was assessed using certified reference samples and by comparing the results for these standards and real dust samples with those from atomic absorption spectrophotometry. (author). 13 refs., 1 fig., 6 tabs
Additional details
Additional titles
- Augmented title (English)
- Differential pulse anodic stripping voltammetry (DPASV)
Publishing Information
- Journal Title
- Bulletin of Electrochemistry
- Journal Volume
- 9
- Journal Issue
- 11-12
- Journal Page Range
- p. 589-591.
- ISSN
- 0256-1654
- CODEN
- BUELE6
INIS
- Country of Publication
- India
- Country of Input or Organization
- India
- INIS RN
- 27009999
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Descriptors DEI
- ABSORPTION SPECTROSCOPY; CADMIUM; DUSTS; INTERFERING ELEMENTS; LEAD; PH VALUE; QUANTITATIVE CHEMICAL ANALYSIS; TRACE AMOUNTS; VOLTAMETRY
- Descriptors DEC
- CHEMICAL ANALYSIS; ELEMENTS; METALS; SPECTROSCOPY