Published November 1994
| Version v1
Journal article
Determination of impurity elements in aluminium
Creators
- 1. Academia Sinica, Beijing, BJ (China). Inst. of Atomic Energy
Description
Twenty five impurity elements in aluminium applied as reactor material are determined. Ti and Ni are determined with epithermal neutron activation analysis (NAA), Mg and Si by inductance coupling plasma emission spectra, other elements by thermal NAA. The fission coefficient of uranium is given by an experiment, the interferences of uranium to Ce, Nd, Mo, Zr, La, Sm are subtracted. The detection limits of these methods are calculated
Additional details
Publishing Information
- Journal Title
- Nuclear Science and Techniques
- Journal Volume
- 5
- Journal Issue
- 4
- Journal Page Range
- p. 241-245.
- ISSN
- 1001-8042
- CODEN
- NSETEC
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 26049310
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Descriptors DEI
- ALUMINIUM; COUPLING; EMISSION SPECTROSCOPY; EPITHERMAL NEUTRONS; IMPURITIES; INTERFERENCE; MNS REACTOR; MULTI-ELEMENT ANALYSIS; NEUTRON ACTIVATION ANALYSIS; PLASMA; QUALITY ASSURANCE; SENSITIVITY; THERMAL NEUTRONS; URANIUM
- Descriptors DEC
- ACTINIDES; ACTIVATION ANALYSIS; BARYONS; CHEMICAL ANALYSIS; ELEMENTARY PARTICLES; ELEMENTS; FERMIONS; HADRONS; METALS; NEUTRONS; NONDESTRUCTIVE ANALYSIS; NUCLEONS; REACTORS; RESEARCH AND TEST REACTORS; RESEARCH REACTORS; SPECTROSCOPY