Published 1991 | Version v1
Report Open

Status of the uranium upgrade of ATLAS

Description

The ATLAS Positive Ion Injector (PII) is designed to replace the tandem injector for the ATLAS heavy-ion facility. When the PII project is complete, ATLAS will be able to accelerate all ions through uranium to energies above the Coulomb barrier. PII consists of an ECR ion source on a 350 KV platform and a very low-velocity superconducting linac. The linac is composed of an independently-phased array of superconducting four-gap interdigital resonators which accelerate over a velocity range of .007c to .05c. the PII project is approximately 75% complete. Beam tests and experiments using the partially completed PII have demonstrated that the technical design goals are being met. The design, construction status, and results of recent operational experience using the PII will be discussed. 10 refs., 2 figs., 1 tab

Availability note (English)

MF available from INIS under the Report Number; OSTI as DE91012474; NTIS; INIS; US Govt. Printing Office Dep.

Files

22085089.pdf

Files (139.4 kB)

Name Size Download all
md5:c095ef35f066f7839a65180a49e4892a
139.4 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
3 p.
Report number
ANL/CP--72009

Conference

Title
1991 Institute of Electrical and Electronics Engineers (IEEE) particle accelerator conference (PAC).
Dates
6-9 May 1991.
Place
San Francisco, CA (USA).

INIS

Optional Information

Contract/Grant/Project number
Contract W-31109-ENG-38
Funding organization
USDOE, Washington, DC (USA).
Secondary number(s)
CONF-910505--73.