Published 1991 | Version v1
Report Open

Simultaneous determination of nitric acid and uranium concentrations in aqueous solution from measurements of electrical conductivity, density, and temperature

Description

Nuclear fuel reprocessing plants handle aqueous solutions of nitric acid and uranium in large quantities. Automatic control of process operations requires reliable measurements of these solutes concentration, but this is difficult to directly measure. Physical properties such as solution density and electrical conductivity vary with solute concentration and temperature. Conductivity, density and temperature can be measured accurately with relatively simple and inexpensive devices. These properties can be used to determine solute concentrations will good correlations. This paper provides the appropriate correlations for solutions containing 2 to 6 Molar (M) nitric acid and 0 to 300 g/L uranium metal at temperatures from 25--90 degrees C. The equations are most accurate below 5 M nitric acid, due to a broad maximum in the conductivity curve at 6 M. 12 refs., 9 figs., 6 tabs

Availability note (English)

MF available from INIS under the Report Number; OSTI as DE91014567; NTIS; INIS; US Govt. Printing Office Dep.

Files

22088398.pdf

Files (691.9 kB)

Name Size Download all
md5:e346e09e9aa0a6c79bf45e8025632e94
691.9 kB Preview Download

Additional details

Additional titles

Subtitle (English)
Consolidated Fuel Reprocessing Program

Publishing Information

Imprint Pagination
37 p.
Report number
CONF-910901--1

Conference

Title
4. international conference on facility operations/safeguards interface.
Dates
29 Sep - 4 Oct 1991.
Place
Albuquerque, NM (USA).

Optional Information

Contract/Grant/Project number
Contract AC05-84OR21400
Funding organization
USDOE, Washington, DC (USA).