CMS structural equilibrium at constant magnetic field as observed by the link alignment system

Description

A study of the time required for the CMS detector to reach structural equilibrium once the magnetic field is ramped to its operational value of 3.8 T is presented. In addition, the results from a stability monitoring at 3.8 T over an eight-month period are given.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nima.2012.01.050

Additional details

Identifiers

DOI
10.1016/j.nima.2012.01.050;
PII
S0168-9002(12)00099-X;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
675
Journal Page Range
p. 84-96