Published May 21, 2012
| Version v1
Journal article
CMS structural equilibrium at constant magnetic field as observed by the link alignment system
Creators
- 1. CIEMAT, Madrid (Spain)
- 2. Instituto de Física de Cantabria, CSIC-University of Cantabria, Santander (Spain)
Description
A study of the time required for the CMS detector to reach structural equilibrium once the magnetic field is ramped to its operational value of 3.8 T is presented. In addition, the results from a stability monitoring at 3.8 T over an eight-month period are given.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.nima.2012.01.050Additional details
Identifiers
- DOI
- 10.1016/j.nima.2012.01.050;
- PII
- S0168-9002(12)00099-X;
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 675
- Journal Page Range
- p. 84-96
- ISSN
- 0168-9002
- CODEN
- NIMAER
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 44115835
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ALIGNMENT; EQUILIBRIUM; MAGNETIC FIELDS; MONITORING; SENSORS; STABILITY
Optional Information
- Copyright
- Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.