Impact of iterative reconstruction on CNR and SNR in dynamic myocardial perfusion imaging in an animal model
Creators
- 1. Klinikum rechts der Isar der Technischen Universitaet Muenchen, Institut fuer Radiologie, Muenchen (Germany)
- 2. ZPF - Zentrum fuer praeklinische Forschung des Klinikum rechts der Isar der Technischen Universitaet Muenchen, Muenchen (Germany)
- 3. Research Group MITI des Klinikums rechts der Isar der Technischen Universitaet Muenchen, Muenchen (Germany)
- 4. Philips Healthcare, Clinical Science (Computed Tomography), Cleveland, OH (United States)
- 5. Philips Healthcare, Physics (Computed Tomography), Cleveland, OH (United States)
Description
To evaluate a new iterative reconstruction (IR) algorithm for radiation dose, image quality (IQ), signal-to-noise-ratio (SNR), and contrast-to-noise-ratio (CNR) in multidetector computed tomography (MDCT) dynamic myocardial perfusion imaging (MPI). ECG-gated 256-slice MDCT dynamic MPI was performed in six pigs after subtotal balloon occlusion of one artery. Two 100 kVp protocols were compared: high dose (HD): 150 mAs; low dose (LD): 100 mAs. HD images were reconstructed with filtered back projection (FBP), LD images with FBP and different strengths of IR (L1, L4, and L7). IQ (5-point scale), SNR, and CNR (ischemic vs. normal myocardium) values derived from the HD (FBP) images and the different LD images were compared. Mean SNR values for myocardium were 16.3, 11.3, 13.1, 17.1, and 28.9 for the HD, LD (FBP), LD (L1), LD (L4), and LD (L7) reconstructions, respectively. Mean CNR values were 8.9, 6.3, 7.8, 9.3, and 12.8. IQ was scored as 4.6, 3.3, 4.4, 4.7, and 3.4, respectively. A significant loss of IQ was observed for the LD (L7) images compared to the HD (FBP) images (P < 0.05). Appropriate levels of iterative reconstruction can improve SNR and CNR, facilitating radiation dose savings in CT-MPI without influencing diagnostic quality. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-012-2525-zAdditional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 22
- Journal Issue
- 12
- Journal Page Range
- p. 2654-2661
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 44007884
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ALGORITHMS; BIOMEDICAL RADIOGRAPHY; BLOOD CIRCULATION; BLOOD FLOW; COMPUTERIZED TOMOGRAPHY; IMAGE PROCESSING; ISCHEMIA; ITERATIVE METHODS; MYOCARDIUM; PERFUSED ORGANS; RADIATION DOSES; SIGNAL-TO-NOISE RATIO; X-RAY RADIOGRAPHY
- Descriptors DEC
- ANEMIAS; BODY; CALCULATION METHODS; CARDIOVASCULAR DISEASES; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DIMENSIONLESS NUMBERS; DISEASES; DOSES; HEART; HEMIC DISEASES; INDUSTRIAL RADIOGRAPHY; MATERIALS TESTING; MATHEMATICAL LOGIC; MEDICINE; MUSCLES; NONDESTRUCTIVE TESTING; NUCLEAR MEDICINE; ORGANS; PROCESSING; RADIOLOGY; SYMPTOMS; TESTING; TOMOGRAPHY; VASCULAR DISEASES