Published May 15, 2011 | Version v1
Journal article

Electro-spark alloying using graphite electrode on titanium alloy surface for biomedical applications

  • 1. Northwestern Polytechnical University, Xi'an 710072 (China) and Xi'an University of Architecture and Technology, Xi'an 710055 (China)
  • 2. Northwestern Polytechnical University, Xi'an 710072 (China)
  • 3. Xi'an University of Architecture and Technology, Xi'an 710055 (China)
  • 4. Fourth Military Medical University, Xi'an 710032 (China)

Description

In order to improve the biomedical properties of a titanium alloy surface, electro-spark surface alloying was carried out using a graphite electrode in air, in a nitrogen gas atmosphere and in silicone oil. The morphology and microstructure of the strengthened layers were analyzed using scanning electron microscopy (SEM) and X-ray diffraction (XRD). The hardness distributions as a function of depth were measured by a micro-hardness tester. Corrosion resistance capacities of the modified layers were evaluated using potentiodynamic polarization measurements and electrochemical impedance spectroscopy (EIS). In addition, wear resistance and corrosive wear properties in a simulated body fluid (SBF) were studied with a pin-on-disk tribometer. Alloyed layers, completely covering the substrate surface and about 40 μm thick mainly composed of the TiC phase and with strong metallurgical bonding and adhesion to the substrate, were obtained. This can markedly improve hardness and wear resistance of the surface layer of the substrate. In comparison to coatings prepared in air and nitrogen gas atmospheres, the coating produced in silicone oil media exhibits a denser and more perfect surface structure. The wear resistance in air and corrosive wear resistance in SBF solution is the best for the coating produced in silicone oil. For instance, the wear rate in air with a GCr15 steel ball counterpart is reduced by a factor of 29 compared with the original titanium alloy and the corrosive wear rate in SBF solution with a corundum ball can decrease by a factor of 13.8. Simultaneously, the effect of electron-spark surface alloying of the titanium alloy surface on biocompatibility and biological activity was also investigated. The electron-spark surface strengthened layer treated in silicone oil shows good biocompatibility and biological activity, and can help cell attachment to the substrate surface.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.apsusc.2011.01.120

Additional details

Identifiers

DOI
10.1016/j.apsusc.2011.01.120;
PII
S0169-4332(11)00156-5;

Publishing Information

Journal Title
Applied Surface Science
Journal Volume
257
Journal Issue
15
Journal Page Range
p. 6364-6371
ISSN
0169-4332
CODEN
ASUSEE

Optional Information

Copyright
Copyright (c) 2011 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.