Published November 2007 | Version v1
Journal article

Efficiency of water radioluminescence under exposure to accelerated electrons

  • 1. FGUP RFYaTs - VNII Ehksperimental'noj Fiziki, Sarov Nizhegorodskoj Obl. (Russian Federation)

Description

Under the normal conditions one managed to ensure ∼1.7x10-6 distilled water radioluminescence efficiency. To excite water luminescence one made use of up to 230 keV energy accelerated electron beam. The luminescence was transmitted to the photomultiplier photocathode by means of a quartz fiber light guide. The recording system was calibrated by means of the comparison ribbon lamp. The absorbed dose in the water was recorded by the film dosimeters

Abstract (Russian)

В нормальных условиях получена эффективность радиолюминесценции дистиллированной воды ∼ 1.7x10-6. Для возбуждения свечения воды использовался пучок ускоренных электронов с энергией до 230 кэВ. Свет передавался на фотокатод ФЭУ кварцевым волоконным световодом. Калибровка регистрирующей системы осуществлялась с помощью эталонной ленточной лампы. Поглощенная доза в воде регистрировалась пленочными дозиметрами

Additional details

Additional titles

Original title (Russian)
Эффективност' радиолюминесценции воды под действием ускоренных электронов

Publishing Information

Journal Title
Pribory i Tekhnika Ehksperimenta
Journal Issue
no.6
Journal Page Range
p. 47-49
ISSN
0032-8162
CODEN
PRTEAJ

Optional Information

Notes
12 refs., 4 figs.