Published 2006 | Version v1
Miscellaneous

SANS facility at the Pitesti 14 MW Triga reactor

  • 1. Institute for Nuclear Research - Pitesti (Romania)
  • 2. National Institute of Materials Physics (NIMP) Bucharest (Romania)
  • 3. National Institute of Physics and Nuclear Engineering Bucharest (Romania)
  • 4. Joint Institute for Nuclear Research Dubna (Russian Federation)
  • 5. National College Al. Odobescu Pitesti (Romania)

Description

Full text of publication follows: At the present time, an important not yet fully exploited potentiality is represented by the SANS instruments existent at lower power reactors and reactors in developing countries even if they are, generally, endowed with a simpler equipment and are characterized by the lack of infrastructure to maintain and repair high technology accessories. The application of SANS at lower power reactors and in developing countries nevertheless is possible in well selected topics where only a restricted Q range is required, when scattering power is expected to be sufficiently high or when the sample size can be increased at the expense of resolution. Examples of this type of applications are: 1) Phase separation and precipitates in material science, 2) Ultrafine grained materials (nano-crystals, ceramics), 3) Porous materials such as concretes and filter materials, 4) Conformation and entanglements of polymer-chains, 5) Aggregates of micelles in microemulsions, gels and colloids, 6) Radiation damage in steels and alloys. The need for the installation of a new SANS facility at the Triga Reactor of the Institute of Nuclear Researches in Pitesti, Romania become actual especially after the shutting down of the VVRS Reactor from Bucharest. A monochromatic neutron beam with 1.5 Angstrom ≤ λ ≤ 5 Angstrom is produced by a mechanical velocity selector with helical slots.The distance between sample and detectors plane is (5.2 m ). The sample width may be fixed between 10 mm and 20 mm. The minimum value of the scattering vector is Qmin = 0.005 Angstrom-1 while the maximal value is Qmax = 0.5 Angstrom-1. The relative error is ΔQ/Qmin = 0.5. The cooperation partnership between advanced research centers and the smaller ones from developing countries could be fruitful. The formers act as mentors in solving specific problems. Such a partnership was established between INR Pitesti, Romania and JINR Dubna, Russia. The first step in this cooperation consists in the manufacturing at Dubna of a battery of gas filled positional detectors devoted to the SANS instrument from Pitesti. (authors)

Availability note (English)

Available in abstract form only, full text entered in this record

Additional details

Publishing Information

Imprint Pagination
1 p.
Report number
INIS-FR--4818

Conference

Title
from basic research to high-tech industry
Acronym
ENC 2005, European Nuclear Conference. Nuclear power for the 21. century
Dates
11-14 Dec 2005
Place
Versailles (France)