Injecting into AmPS when ring cavity operates at 476 MHz
Description
The RF requirements for the two modes of AmPS, Stretcher Mode and Storage Mode, are different. In Storage Mode, as is shown in this report, it is more practical to operate at a lower RF-frequency than fRF=2856MHz, which is the RF-frequency in Stretcher Mode. A few consequences of operating the ring cavity at a lower frequency than the (injecting) linac frequency will be reviewed. (author). 1 ref.; 4 figs
Availability note (English)
MF available from INIS under the Report Number.Files
23075579.pdf
Files
(275.7 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:0b135316a4299b361f9909a3b40053f5
|
275.7 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 10 p.
- Report number
- NIKHEF-K-AmPS--91-08
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Netherlands
- INIS RN
- 23075579
- Subject category
- S43: PARTICLE ACCELERATORS;
- Descriptors DEI
- BEAM INJECTION; CAVITY RESONATORS; MEA LINAC; RF SYSTEMS
- Descriptors DEC
- ACCELERATORS; ELECTRONIC EQUIPMENT; EQUIPMENT; LINEAR ACCELERATORS; RESONATORS