Published 2016
| Version v1
Report
Problems and mistakes of the biodosimetry
Creators
- 1. Institute of Genetics and Cytology of the National Academy of Sciences, Minsk (Belarus)
Description
Automatic translation: When cells of the same donor are irradiated in vitro, there is a strict dependence of the frequency of aberrations on the radiation dose. However, the results of in vivo biodosimetry differ from those in vitro. For example, when the doses received by the liquidators of the Chernobyl accident were determined by the cytogenetic dosimetry method, in almost 70% of cases the data significantly differed from the readings of traditional dosimeters.
Abstract (Russian)
При облучении in vitro клеток одного и того же донора наблюдается строгая зависимость частоты аберраций от дозы радиации. Однако результаты биодозиметрии in vivo отличаются от таковых in vitro. Например, при определении методом цитогенетической дозиметрии доз, полученных ликвидаторами Чернобыльской аварии, почти в 70% случаев данные существенно отличались от показаний традиционных дозиметров.Additional details
Additional titles
- Original title (Russian)
- Проблемы и ошибки биодозиметрии
Publishing Information
- Imprint Title
- Health Effects of Chernobyl: Prediction and Actual Data 30 Years After the Accident. International Conference. Collection of Abstracts
- Imprint Pagination
- 191 p.
- Journal Page Range
- p. 96
- Report number
- INIS-RU--21O0252
Conference
- Title
- Prediction and Actual Data 30 Years After the Accident
- Acronym
- International Conference on Health Effects of Chernobyl
- Dates
- 17-19 May 2016
- Place
- Obninsk (Russian Federation)
INIS
- Country of Publication
- Russian Federation
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 52059450
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CHERNOBYLSK-4 REACTOR; DOSEMETERS; DOSIMETRY; IN VITRO; IN VIVO; IRRADIATION; MELTDOWN; POPULATION RELOCATION; RADIATION ACCIDENTS; RADIATION DOSES; SURFACE CONTAMINATION
- Descriptors DEC
- ACCIDENTS; BEYOND-DESIGN-BASIS ACCIDENTS; CONTAMINATION; DOSES; ENRICHED URANIUM REACTORS; GRAPHITE MODERATED REACTORS; LWGR TYPE REACTORS; MEASURING INSTRUMENTS; POWER REACTORS; REACTOR ACCIDENTS; REACTORS; SEVERE ACCIDENTS; THERMAL REACTORS; WATER COOLED REACTORS
Optional Information
- Lead record
- zjch4-vvg67
- Notes
- Document from Chernobyl Technical Cooperation Project RER7010 Imprint:#041C##0435##0434##0438##0446##0438##043D##0441##043A##0438##0435# #0440##0430##0434##0438##043E##043B##043E##0433##0438##0447##0435##0441##043A##0438##0435# #043F##043E##0441##043B##0435##0434##0441##0442##0432##0438##044F# #0427##0435##0440##043D##043E##0431##044B##043B##044F#: #041F##0440##043E##0433##043D##043E##0437# #0438# #0444##0430##043A##0442##0438##0447##0435##0441##043A##0438##0435# #0434##0430##043D##043D##044B##0435# #0441##043F##0443##0441##0442##044F# 30 #043B##0435##0442#