Published April 26, 1978 | Version v1
Report Open

Radiative heat transfer in a 19-pin sodium-voided bundle

Description

A theoretical study was made of the radiative heat removal capability in a 19-pin bundle simulating the fuel assemblies of the commercial-scale (217-pin) Clinch River Breeder Reactor. Pin surface temperature distributions and the maximum allowable uniform pin power (without causing cladding meltdown) were determined for a range of emissivities and duct-wall temperatures. It was concluded that radiative heat transfer ranging to 0.1 kW/ft was comparable to free convection ranging to 0.02 kW/ft, and was lower than that of forced convection cooling to 2.17 kW/ft by the sodium vapor

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A03/MF A01.

Files

10452298.pdf

Files (743.7 kB)

Name Size Download all
md5:24c6bc0bb16a11dc66d9a7d31ee153e0
743.7 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
46 p.
Report number
ORNL/MIT--274